start_day#
Start day input in CLI interactive dialogue. May take values from 1 to 6, 1 is default. Input and result series start at day 1 in the first week, even if start_day>1. (unit: none)
mpi_path#
Full path to MPI bin folder, for example C:\Program Files\Microsoft MPI\Bin. (unit: none)
inflow_model#
The type of inflow model used in optimization (lognormal, principal, residual) (unit: none)
min_discharge_cost_d_price#
Cost of violating minimum discharge constraint (unit: EUR/MWh)
read_head_coefficients#
Set to 0 to skip reading head coefficients from result files. (unit: none)
relaxation_tolerance#
Tolerance in the relaxation process (unit: none)
log_file_path#
The full path to the directory where the session log file will be written. Default: Folder ‘LogFiles’ in prodriskPath. (unit: none)
read_start_time_water_values#
Read water values at start time from result file indvan.prd. (unit: none)
overflow_cost#
Penalty cost for reservoir overflow. (unit: EUR/MWh)
last_iteration_generated_scenarios#
Last iteration where generated scenarios are included in the optimization (unit: none)
min_bypass_cost_volume#
Cost of violating minimum bypass constraint (unit: EUR/1000m3)
inf#
Used as unlimited for certain variables in weekly LP problems. (unit: none)
cut_negative_residual_inflow#
If the residual inflow model is used (setting residual_model=1), cut negative inflows to zero if this setting is 1 (recommended, default). (unit: none)
water_ration_cost#
Penalty cost for breaking min filling restrictions. (unit: EUR/MWh)
cuts_as_endvalue_setting#
Use input cuts as end value setting (if provided) if set to 1. Default value is 0. (unit: none)
min_iterations#
Min number of SDDP iterations run (unit: none)
is_series_simulation#
Set to 1 to enable series simulation mode (used for investment planning) (unit: none)
sim_convex#
Adds command line option -SIMCONVEX. This ensures same model is used in the forward and backward iterations. (unit: none)
min_reservoir_cost_volume#
Cost of violating minimum reservoir constraint (unit: EUR/1000m3)
n_sample_scenarios#
Number of sampled inflow scenarios to generate percentiles or extremes from (unit: none)
ramping_down_cost_volume#
Cost of violating ramping down constraint. (unit: EUR/1000m3)
min_discharge_cost_energy#
Cost of violating minimum discharge constraint (unit: EUR/MWh)
backward_spilling_cost_volume#
Cost of spilling in backward recursion (unit: EUR/1000m3)
ramping_up_cost_energy#
Cost of violating ramping up constraint. (unit: EUR/MWh)
buffer_reservoir_cost_energy#
Cost of deviating from the guideline curve for buffer reservoirs (unit: EUR/MWh)
command_line_option#
Command line option, see the Prodrisk documentation (unit: none)
prepare_shop_input#
Create cut file(s) for SHOP (SHOP, Ja in interactive dialogue). (unit: none)
surplus_power_cost#
Penalty cost for surplus power. (unit: EUR/MWh)
head_coeff_and_cut_id#
Setting this value to 0 together with cut input will force a -NOHEAD run. In -SIM runs with no head coefficients set, this id must either be set to 0, or the -NOHEAD option should be used. (unit: none)
bypass_cost#
Global bypass cost (unit: EUR/MWh)
n_principal_comp#
The number of principal components in the inflow model (unit: none)
read_lognormal_model#
If set to 1, Prodrisk will read and use a pre-existing lognormal model for inflow (unit: none)
user_defined_price_model#
Take area->priceBand and area->priceTransition as input and skip GENPRIS (unit: none)
backward_spilling_cost_energy#
Cost of spilling in backward recursion (unit: EUR/MWh)
n_kmeans#
Number of sample points used in K means clustering (unit: none)
end_week_new_cuts#
End week for calculating new cuts, option#5 in CLI interactive dialogue. Cuts given as input for later weeks are used in the final simulation of the whole simulation period. (unit: none)
future_cost#
Future cost for the cuts to SHOP (unit: kEUR)
first_relaxation_parameter#
Parameter in the relaxation process (unit: none)
shop_file_name#
Prefix to the file names of the SHOP-files copied to shop_directory. Default: ‘SHOP-SYSTEM’. (unit: none)
deficit_power_cost#
Penalty cost for deficit power. (unit: EUR/MWh)
reservoir_balance_option#
Reservoir balances during the week. Default 0 (weekly reservoir balances) (unit: none)
backward_bypass_cost_volume#
Cost of bypassing in backward recursion (unit: EUR/1000m3)
min_discharge_cost_volume#
Cost of violating minimum discharge constraint (unit: EUR/1000m3)
read_shop_water_values#
Read cuts from result file SHOP-SYSTEM.dat (standard SHOP cut format). Currently only available in the WCF interface. (unit: none)
read_mean_reservoir_trajectories#
Set to 0 to skip reading mean reservoir trajectories from result files. (unit: none)
use_reserve_up#
Set to 1 to include reserve up capacity market (unit: none)
price_scenario_option#
Reserved for future use (?): feature with multiple price scenarios per inflow scenarios currently not available through the API. (unit: none)
shop_cut_week#
Week number standard SHOP cut file should be made for. May be set to 1 or 2. Default value is 1. (unit: none)
temp_dir#
Path to where temp working dir should be created. Special characters are forbidden. Default: prodriskPath. (unit: none)
write_penalty_logfiles#
Set to 1 to make detailed penalty information available. Default is 0, as this might increase the computation time. (unit: none)
alfa_max#
Used as unlimited for objective function in weekly LP problems. (unit: none)
min_iterations_without_generated_scenarios#
Minimum number of iterations without generated scenarios at the end of the optimization (unit: none)
use_input_pq_curve#
Binary option: 1 = use input PQ curve 0 = make PQ curve convex (unit: none)
ignore_headcoeff_meanres#
If nonzero, head coefficients and mean reservoir trajectories are ignored even if set as input. (unit: none)
price_periods#
The hours of each week are aggregated into price periods with the same price to save simulation time. This aggregation is represented as a time series, where each hour in the week is given a tag to represent the corresponding price period. Three different time resolutions may be used for different set of weeks in an optimization: sequential price period, accumulated price periods and weekly resolution. (unit: none)
n_price_levels#
The number of price levels used in the price model, including max and min. (unit: none)
min_iterations_first_run#
Min. no. of iterations in initial strategy computation (to compute head coefficients) (unit: none)
ramping_down_cost_energy#
Cost of violating ramping down constraint. (unit: EUR/MWh)
reference_price#
Reference price for the calculation of water values for SHOP (unit: EUR/MWh)
node_price_profile#
Set to 1 to use the Node dependent price profile functionality. (unit: none)
forward_spilling_cost_d_price#
Cost of spilling in forward simulation (unit: EUR/MWh)
sequential_price_period_end_week#
Last week with sequential price period resolution (unit: none)
use_reserve_down#
Set to 1 to include reserve down capacity market (unit: none)
suppress_seq_res#
Set to 0 to get all module results with sequential price period resolution (unit: none)
windows_core_delay#
Safety delay before envoking core programs on temporary run directory on Windows systems. Default 10000ms. (unit: ms)
backward_bypass_cost_energy#
Cost of bypassing in backward recursion (unit: EUR/MWh)
n_principal_comp_discrete_values#
The number of discrete values for each principal component (unit: none)
forward_model_option#
1 - Forward simulation as final simulation, 0 - Convex forward simulation (unit: none)
max_iterations_first_run#
Max. no. of iterations in initial strategy computation (to compute head coefficients) (unit: none)
shop_directory#
Path to where SHOP files should be copied. (unit: none)
prodrisk_path#
The full path to the folder containing the .exe and .dll files for running Prodrisk (unit: none)
lognormal_model#
If set to 1, the lognormal model for inflow will be used (unit: none)
forward_spilling_cost_volume#
Cost of spilling in forward simulation (unit: EUR/1000m3)
second_relaxation_parameter#
Parameter in the relaxation process (unit: none)
forward_bypass_cost_volume#
Cost of bypassing in forward simulation (unit: EUR/1000m3)
min_bypass_cost_energy#
Cost of violating minimum bypass constraint (unit: EUR/MWh)
use_coin_osi#
Binary variable to choose between running Prodrisk with OSI (1) or CPLEX (0). Default is 0. (unit: none)
max_reservoir_cost_volume#
Cost of violating maximum reservoir constraint (unit: EUR/1000m3)
inflow_seasons#
Define inflow seasons by setting a unique integer tag at the beginning of the first week of each season. A negative tag means that correlations will be zeroed in that season. Default: One season spanning over the whole simulation period. (unit: none)
n_processes#
The number of processes to run in parallel in the simulation (unit: none)
shop_cut_weeks#
Week numbers extended SHOP cut files should be made for. (unit: none)
print_all#
Adds command line option -printall. Will give some more detailed logging, including a file with F-cost per scenario per iteration. (unit: none)
max_cuts_created#
Number of cuts created (unit: none)
log_file_name#
The name of the session log file, including the file extension (the content is always plain text). By default, the name is inherited from the Prodrisk session and has the format ‘session_YYYY-MM-DD-hh-mm-ss.txt’ (with a time stamp), unless the name of the session is set otherwise (pyprodrisk: with sim_id). (unit: none)
backward_spilling_cost_d_price#
Cost of spilling in backward recursion (unit: EUR/MWh)
max_reservoir_cost_d_price#
Cost of violating maximum reservoir constraint (unit: EUR/MWh)
ramping_down_cost_d_price#
Cost of violating ramping down constraint. (unit: EUR/MWh)
forward_spilling_cost_energy#
Cost of spilling in forward simulation (unit: EUR/MWh)
aggregated_price_period_start_week#
Use weekly resolution from this week (unit: none)
forward_bypass_cost_energy#
Cost of bypassing in forward simulation (unit: EUR/MWh)
min_reservoir_cost_energy#
Cost of violating minimum reservoir constraint (unit: EUR/MWh)
residual_model#
If set to 1, the residual model for inflow will be used instead of the principal component analysis (unit: none)
buffer_reservoir_cost_d_price#
Cost of deviating from the guideline curve for buffer reservoirs (unit: EUR/MWh)
generated_inflow_type#
Type of generated inflow sampling (0: Random, 1: Percentiles, 2: Extremes) (unit: none)
prodrisk_variant#
Name of Prodrisk executable. May be used on linux to test different MPI versions than Intel MPI. (unit: none)
reservoir_soft_restriction_cost#
Penalty cost for breaking soft reservoir restrictions. (unit: EUR/m3)
backward_bypass_cost_d_price#
Cost of bypassing in backward recursion (unit: EUR/MWh)
sequential_price_period_start_week#
First week with sequential price period resolution (unit: none)
use_non_convex_pq_curve#
Enable feature: non convex PQ curve using integer variables in the final simulation (large computation time!). (unit: none)
ramping_up_cost_volume#
Cost of violating ramping up constraint. (unit: EUR/1000m3)
buffer_reservoir_cost_volume#
Cost of deviating from the guideline curve for buffer reservoirs (unit: EUR/1000m3)
max_reservoir_cost_energy#
Cost of violating maximum reservoir constraint (unit: EUR/MWh)
max_relaxation_iterations#
Maximum number of iterations in the relaxation process (unit: none)
ramping_up_cost_d_price#
Cost of violating ramping up constraint. (unit: EUR/MWh)
forward_bypass_cost_d_price#
Cost of bypassing in forward simulation (unit: EUR/MWh)
min_bypass_cost_d_price#
Cost of violating minimum bypass constraint (unit: EUR/MWh)
convergence_criteria#
Convergence tolerance. (unit: %)
n_generated_scenarios#
Number of generated scenarios to include in the optimization (unit: none)
real_interest_rate#
Real interest rate, used to set weekly discount factors for cash flows in future weeks. (unit: %)
windows_api_delay#
Safety delay when launching processes from the API on Windows systems. Default 3000ms. (unit: ms)
max_iterations#
Max number of SDDP iterations run (unit: none)
min_scenarios_per_price_node#
Minimum number of scenarios per price node in the price model. (unit: none)
min_reservoir_cost_d_price#